Corrosion protection of concrete

3 Surface preparation
KOSTER NB 1 Grey

Corrosion protection on concrete is usually done with a system of KÖSTER LF-BM and KÖSTER PUR-Bitumen, applied by brush or roller. The system is crack bridging.

Alternatives:
In case of minor acid impact, if no crack bridging is required, the coating can alternatively be carried out only with two layers of KÖSTER Bridge Coat.

In the case of extraordinarily high acid impact (e. g. when below the acid dew point) the entire coating is to be carried out with two layers of KÖSTER VE. In addition KOSTER VE is suitable for the covering of edges, holes and screws prior to the application of KOSTER Bridge Coat.

The surface is prepared by sand-blasting, grinding or shot-blasting until a solid and stable substrate for the subsequent coating is ensured.

For reprofiling and concrete replacement KOSTER Repair Mortar NC is applied. It is suitable for trowel application or can be spray applied. The mortar is applied onto the prepared, stable substrate which must also be free of bond inhibiting agents. Reinforcement steel has to be cleaned, as corrosion protection and bonding agent KOSTER Z1 / Z2 is applied.

Rough and highly absorbent substrates are prepared with KOSTER NB 1 “fast”.

Always adhere to the specifications in the respective Technical Guidelines.

Because corrosion protection on concrete requires experience and should be analyzed case by case, please contact our technical consultants. They will be glad to answer your questions.

 

Back

Top
Albania Austria Bosnia and Herzegovina Brasil Bulgaria China Croatia Czech Republic Denmark Finland Germany Ghana Greece Hungary Italy Japan Kazakhstan Kuwait Latvia Lebanon Macedonia Mexico Netherlands New Zealand Norway Panama Poland Portugal Romania Russia Senegal Serbia Slovakia Slovenia South Africa Spain Thailand Turkey Ukraine United Kingdom United States of America